SFRAC Oracle integration - node ID match

Check category: Availability


Check description: Validate that the node ID values between LLT and Oracle Clusterware are the same.


Check procedure:

  • Retrieves the node ID values from the llthosts file.
  • Retrieves the node ID values configured in Oracle Clusterware.
  • Verifies the node ID values set in LLT equals the node ID values set in Oracle clusterware.


Check recommendation: It is recommended that the node ID values between Low Latency Transport (LLT) and Oracle Clusterware should be same.



VCS GAB Startup Configuration Check

Check category: Availability


Check description: Checks if the GAB_START entry in the GAB configuration file is set to 1.


Check procedure:

  • Verifies whether the GAB_START entry in the GAB configuration file is set to 0.


Check recommendation: Make sure that the GAB_START entry in the GAB configuration file is set to 1 so that the GAB module is enabled and ready to startup after system reboot.



VCS GAB jeopardy

Check category: Availability


Check description: Checks if any of the private links in the cluster are in the jeopardy state.


Check procedure:

  • Checks the network connectivity of the target host with the other hosts in the cluster.
  • Checks if any of the private links are in JEOPARDY state.


Check recommendation: 1. Determine the connectivity of this node with the remaining nodes in the cluster. Enter:
/sbin/lltstat -nvv
If the status is DOWN this node cannot see that link to the other node(s).
2. Restore connectivity through this private link.
3. Verify that connectivity has been restored. Enter:
# /sbin/gabconfig -a | /bin/grep jeopardy
If this command does not have any output, the link has been restored.



GAB ports' availability

Check category: Availability


Check description: Checks whether all GAB ports are configured on the system.


Check procedure:

  • Identifies all the GAB ports that are configured on the system.
  • Checks whether the number of GAB ports configured is equal to eight.


Check recommendation: It is recommended that you configure all the GAB ports in the system.



Verify I/O fencing for cluster

Check category: Availability


Check description: Verifies whether I/O fencing is properly configured for cluster.


Check procedure:

  • Determines the fencing mode using the 'vxfenadm' command and verifies whether fencing mode is set to either SCSI-3 or SYBASE or CPS or customized.


Check recommendation: Either I/O fencing is not running on the system or fencing mode is not configured properly. It is recommended to configure I/O fencing with fencing mode configured as per product requirements when using SFCFS to avoid VxFS file system corruption.



Package Consistency

Check category: Availability


Check description: Checks that packages installed across all the nodes in a cluster are consistent


Check procedure:

  • Identifies the packages installed on all the nodess in a cluster.
  • Verifies that the package installed and its version are consistent across all the nodes in the cluster.


Check recommendation: Ensure that packages installed on all the nodes in a cluster are consistent and package versions are identical. Inconsistent packages can cause errors in application fail-over.



Processor speed

Check category: Availability


Check description: Checks whether the processors have the same clock cycle frequency across the cluster.


Check procedure:

  • Determines the CPU speed of each system in the SFRAC cluster.
  • Verifies whether the CPU speed is same across all nodes in the cluster.


Check recommendation: All nodes in a cluster must have identical processors with the same clock cycle frequency.



Verify software patch level

Check category: Best practices


Check description: Checks whether the installed Storage Foundation / InfoScale products are at the latest software patch level.


Check procedure:

  • Identifies all the Storage Foundation / InfoScale products installed on the system.
  • Verifies whether the installed products have the latest software versions that are available for download.